Product Safety Measures
1. Use
DC Resistance TesterRead this manual carefully before use.
2.
DC Resistance TesterOperators should have basic knowledge of electrical equipment.
3.
DC Resistance TesterCan be used indoors and outdoors, but avoid rain, corrosive gas, excessive dust, high temperature, and direct sunlight.
4. Avoid severe vibration.
5. Maintenance and adjustment by qualified personnel only.
6. Turn off power before removing test leads.
7. Wait for discharge to stop before switching taps.
8. Do not move test clips or power supply wiring during testing.
Performance & Technical Specs
1. Output Current & Range: 0-20A, range
0.2mW-20KW
|
Current |
Range |
Current |
Range |
|
20A |
0.2mW-1W |
1A |
10mW-20W |
|
10A |
1mW-2W |
0.5A |
50mW-40W |
|
5A |
1mW-4W |
5mA |
20W-4KW |
Note: for ranges beyond the above, please use the auto-test function.
2. Test Accuracy: 0.2%, Max Resolution: 0.1mW.
3. 65K true color LCD display with Chinese menu prompts for easy operation.
4. Large storage, 2000 test records,
5. Power Supply: AC220V±10%
6. Operating Temperature: -10C~40C.
7. Operating Humidity: <80%RH.
8. Weight: 6kg.

Note: The above information and technical parameters are compiled and published by Yangzhou Darui Electric Co., Ltd.